Item | Specification | |
Power Supply | Rated Supply Voltage | Three-phase 380V-20%~415V+20%.50~60Hz±5%,Voltage imbalance rate<3% |
Output | Max Output Voltage | The maximum output voltage is the same as the input supply voltage |
Output Current Rating | 100% Rated current continuous output | |
Maximum Overload Current | 150% rated current 60s,180% rated current 10s,200% rated current 2s | |
Basic Control Specification |
drive mode | (FVC) |
Input mode | Position input, speed input, torque input | |
Start-stop control mode | keyboard, control terminal, communication | |
Speed control range | 0~32000rpm | |
Input frequency resolution | Digital input:1rpm Analog input: 0.1% of maximum speed | |
Speed range | 0.736111111 | |
Speed Control Accuracy | ±0.2% Rated synchronous speed | |
Acceleration and deceleration time | 0.01s~650.00s | |
Starting torque | 200%/0rpm | |
Torque Control Accuracy | ±5% Rated torque | |
Output voltage self-adjusting | The input voltage changes, the output voltage remains basically unchanged | |
Automatic current limit | Automatically limit the output current to avoid frequent over-current tripping | |
Signal input | Communication, multi-speed, analog, external high-speed pulse, etc. | |
Input and Output | Reference power | 10V/20mA |
Terminal Control Power | 24V/200mA | |
Digital input terminal | 7(X1~X7)digital multi-function input | |
Analog input terminal | 2(AI1~AI2) Analog input | |
Voltage source -10 ~ 10V input; | ||
Digital output terminal | 4(Y1~Y4) Multifunctional digital output | |
Y1~Y2 Maximum output current 50mA | ||
Analog output terminal | 2-way (AO1/AO2) multi-function analog output terminals, which can output 0~10V | |
Keyboard Display | LED Display | LED digital tube display driver related information |
Protection | Protection | Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheating, overspeed and external faults, etc. |
Use condition | Installation site | Indoor, below 1 km above sea level, free from dust, corrosive gas and direct sunlight |
Applicable environment | -10ºC~+40ºC,20%~90%RH(no condensation) | |
Vibration | <0.5g | |
Storage environment | -25ºC~+65ºC | |
Installation method | Wall-mounted, floor electric control cabinet, through-wall | |
Protection degree | IP20/IP21(Up to 450kW) | |
Type of cooling | Forced air cooling |