BR100 Series
Energy Consumption Braking Unit
Product Description
The BR100 series braking unit has the stable and reliable working performance and protection against over-temperature and braking resistor short circuit, and can be used for inverter-driven lifting equipment, centrifuges, washing machines, spin dryers, and rapid parking. It can change the electric energy generated by the motor in the power generation state into the thermal energy to be used by the braking resistor. In addition, it is easy to use and compatible with inverters of various brands.
Product Parameters
Item |
Specifications |
Control Mode |
Output Voltage Control |
Auto-modulated switch-mode |
Brake Voltage |
Varies with models 395V,420V,675V(Standard),720V,1135V |
Protection |
Over-heating,Short-Circuit |
Overheating Trip |
80°C(Heatsink) |
Display |
LED |
Power indicator,Brake indicator,Fault indicator |
Application Conditions |
Installation Site |
Indoor,with altitude less than 1000 meters,free of dust and corrosive gas,and no direct |
Ambient Temperature |
-10ºC~+40+40+40ºC. In the temperature range +40ºC…+50 °C, the rated output current is decreased by 1% for every additional 1°C
20%-90%RH(no condensation) |
Vibration |
<0.5g |
Storage Temperature |
-20ºC to +65ºC |
Installation Method |
Wall mounting |
Degree of Protection |
Degree of Protection |
IP20 |
Cooling Method |
Cooling Method |
Self -cooling (BR100-045,BR100-160)
Air cooling (BR100-315,BR100-220-6) |
Installation Instructions