| Item | 
      Specification | 
     
     
      | Power supply | 
      Rated voltage of power supply | 
      Three-phase 340V-10% to 460V+10% 50-60Hz ± 5%; voltage unbalance rate: <3% | 
     
     
      | Output | 
      Maximum output voltage | 
      The maximum output voltage is the same as the input power voltage. | 
     
     
      | Rated output current | 
      Continuous output of 100% rated current | 
     
     
      | Maximum overload current | 
      G model: 150% rated current for 60s P model: 120% rated current for 60s (2kHz carrier; please derate for carriers above this level) | 
     
     
      | Basic control  | 
      Driving mode | 
      V/F control (VVF); Speed sensorless vector control (SVC) Speed sensor vector control (FVC) | 
     
     
      | Input mode | 
      Frequency (speed) input, torque input | 
     
     
      | Start and stop control mode | 
      Keyboard, control terminal (two-line control and three-line control),communication | 
     
     
      | Frequency control range | 
      0.00~600.00Hz/0.0~3000.0Hz | 
     
     
      | Input frequency resolution | 
      Digital input: 0.01Hz Analog input: 0.1% of maximum frequency | 
     
     
      | Speed control range | 
      1:50 (VVF), 1:200 (SVC), 1:1000 (FVC) | 
     
     
      | Speed control accuracy | 
      ±0.5% (VVF), ±0.2% (SVC), ±0.02% (FVC) | 
     
     
      | Acceleration and deceleration time | 
      0.01s~600.00s/0.1s~6000.0s/1s~60000s | 
     
     
      | Voltage/frequency characteristics | 
      Rated output voltage 20%~100% adjustable, reference frequency 1Hz~600Hz/3000Hz adjustable | 
     
     
      | Torque boost | 
      Fixed torque boost curve, any V/F curve optional | 
     
     
      | Starting torque | 
      150%/3Hz (VVF), 150%/0.25Hz (SVC), 180%/0Hz (FVC) | 
     
     
      | Torque control accuracy | 
      ±5% rated torque (SVC), ±3% rated torque (FVC) | 
     
     
      | Self-adjustment of output voltage | 
      When the input voltage changes, the output voltage will basically remain unchanged. | 
     
     
      | Automatic current limit | 
      Output current is automatically limited to avoid frequent overcurrent trips. | 
     
     
      | DC braking | 
      Braking frequency: 0.01 to maximum frequency Braking time: 0~30S Braking current: 0%~150% rated current | 
     
     
      | Signal input source | 
      Communication, multi-speed, analog, high-speed pulse, etc. | 
     
     
      | Input and output  | 
      Reference power supply | 
      10.5V±0.5V/20mA | 
     
     
      | Terminal control power | 
      24V/200mA | 
     
     
      | Digital input terminal | 
      7 (standard configuration X1~X7) + 3 (extension card X8~X10)-channel digital multi-function inputs: X7 can be used as a high-speed pulse input terminal (F02.06 = 35/38/40); X1~X6 and X8~X10, totally 9 terminals that can only serve as ordinary digital input terminals | 
     
     
      | Analog input terminal | 
      3 (standard configuration AI1 ~ AI3) + 1 (extension card AI4)-channel analog input: 1-channel AI1: support 0 ~ 10V or -10~ 10V, optional for selection by using function code F02.62; 2-channel AI2/AI3: support 0 ~ 10V or 0~ 20mA or 4~ 20mA, optional for selection by using function code F02.63 and F02.64 is optional; 1-channel AI4: support 0 ~ 10V or -10~ 10V, optional for selection by using function code F02.65 | 
     
     
      | Digital output terminal | 
      2 (standard Y1/Y2) open-collector multi-function outputs + 2 (R1: EA/EB/EC and R2: RA/RB/RC) relay multi-function outputs + 2 (extension card) (R3: RA3/RC3 and R4: RA4/RC4) relay multi-function outputs Maximum output current of the collector: 50 mA; Relay contact capacity 250VAC/3A or 30VDC/1A, with EA-EC and RA-RC normally open, EB-EC and RB-RC normally closed; RA3-RC3, RA4-RC4 normally open | 
     
     
      | Analog output terminal | 
      2-channel (M1/M2) multi-function analog output terminals to output 0~10V or 0~20mA or 4~20mA, optional for selection by using function codes F03.34 and F03.35 | 
     
     
      | Operation panel | 
      LCD display | 
      The LCD digital tube displays relevant information about the inverter. | 
     
     
      | Parameter copying | 
      Parameter settings of the inverter can be uploaded and downloaded for fast parameter copying. | 
     
     
      | Protection | 
      Protective Function | 
      Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, overspeed, load loss, external fault, etc. | 
     
     
      | Use conditions | 
      Location | 
      Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight | 
     
     
      | Applicable environment | 
      -10ºC to +50ºC, derating by 5% per 1ºC increase above 40ºC, 20% to 90%RH (non-condensing) | 
     
     
      | Vibration | 
      Less than 0.5g | 
     
     
      | Storage environment | 
      -40ºC~+70ºC | 
     
     
      | Installation method | 
      Wall-mounted, floor-standing electrical control cabinet, through-wall | 
     
     
      | Protection level | 
      Protection level | 
      Standard IP21/IP20 (remove the plastic cover at the top of the plastic case) | 
     
     
      | Cooling method | 
      Cooling method | 
      Forced air cooling |