Customization: | Available |
---|---|
Application: | General Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main Features:
1. SVC (Sensorless vector control):Torque control accuracy: 5% rated torque. Speed control accuracy: ±0.2% rated synchronous speed.Items | Specifications | |
Input | Rated Voltage | 3-phase 380VAC±20%, 50~60Hz±5%, |
voltage imbalance rate <3% | ||
Output | Output Voltage | 3-phase, from 0 to Usupply. |
Rated Output Current | 100% rated current non-stop output | |
Max. Overload Current | Model G: 150% rated current for 1 minutes, 180% rated current for 10 seconds | |
Model P: 120% rated current for 1 minutes, 150% rated current for 10 seconds | ||
Basic Control Functions | Control Mode | V/F, SVC0, SVC1 |
Input Mode | Frequency (Speed) input, torque input | |
Start/Stop Control Mode | Keypad, control terminals (2-wire sequence, 3-wire sequence), RS485 | |
Frequency Control Range | 0.00~600.00Hz | |
Input Frequency Resolution | Numeric input: 0.01Hz, analog input: 0.1% of maximum frequency | |
Governor Deflection | 1:50(V/F), 1:100(SVC) | |
Speed Control Accuracy | ±0.2% rated synchronous speed | |
Acceleration/Deceleration Time | 0.01~600.00 seconds/minutes | |
V/F Features | Rated output voltage: 20%~100% adjustable | |
Frequency base :20Hz~600Hz adjustable | ||
Torque Boost | Automatic torque boost, fixed torque boost curve, customer defined V/F curve scaling | |
Start Torque | 150%/1Hz(V/F),150%/0.5Hz(SVC) | |
Torque Control Accuracy | ±5% rated torque (SVC1) | |
AVR | AVR is active while output voltage remains unchanged if input voltage is varying. | |
Automatic Current Limit | Automatically limit output current, avoid tripping overcurrent frequently | |
DC Brake | Brake frequency:0.1~60Hz, brake time:0~30S, | |
brake current:0~150% rated current | ||
Signal Input Source | Communication, analog voltage, analog current, preset speed, simple PLC and their combinations | |
Special Function Control | Textile Wobbulation | Achieve textile wobbulation functions like wobbulation range, time and jump |
Function of Input and Output | Reference Power Supply | 10V/20mA |
Terminal Control Power Supply | 24V/150mA | |
Numeric Input Terminals | 7 programmable numeric input terminals | |
Analog Input Terminals | 4 analog inputs:2 voltage inputs (0~10V), and 2 current inputs(0~20mA) | |
Numeric Output Terminals | 2 OC outputs and 1 relay output are programmable. Maximum output current of OC: 50mA. Relay contact capacity: 250VAC/3A or 30VDC/1A. When relay acts, EA-EC is on, and EB-EC is off. | |
Analog output Terminals | 2 programmable analog output terminals can output 0~10V or 0~20mA | |
Keypad Display | LED | Human interactions with displays and control actuators |
Parameter Copy | Upload and download parameter information of the inverter, copy parameters rapidly. | |
Protections | Protections | Short circuit, overcurrent, overload, overvoltage, undervoltage, phase loss, overheating, external fault, and etc. |
Application Conditions | Installation Site | Indoor, with altitude less than 1000 meters, free from dust, corrosive gas, and direct sunlight |
Ambient Temperature | -10ºC~+40ºC. In the temperature range +40 °C…+50 °C, the rated output current is decreased by 1% for every additional 1 °C. 20%~90%RH (no condensation) | |
Vibration | <0.5g | |
Storage Temperature | -25ºC~+65ºC | |
Installation Method | Wall mounting, floor mounting, flush mounting | |
Degree of Protection | Degree of Protection | IP20 |
Cooling Method | Cooling Method | Forced air cooling |