Customization: | Available |
---|---|
Application: | General Transducer |
Output Type: | Triple |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Single-phase/three-phase 220V-240V 0.4kW-2.2kW
Three-phase AC 340V-460V 0.75kW-450kW
Item | Specification | |
Power supply | Rated voltage of power supply | Three-phase 340V-10% to 460V+10%,Single-phase/three-phase 200V-10% to 240V+10%;50-60Hz ± 5%; voltage unbalance rate: <3% |
Output | Maximum output voltage | The maximum output voltage is the same as the input power voltage. |
Rated output current | Continuous output of 100% rated current | |
Maximum overload current | 150% of heavy-duty rated current for 60s (185kW-450kW: 140% of heavy-duty rated current for 60s) 120% of light-duty rated current for 60s |
|
Basic control | Driving mode | V/F control (VVF); speed sensorless vector control (SVC) |
Input mode | Frequency (speed) input, torque input | |
Start and stop control mode | Keyboard, control terminal (two-line control and three-line control), communication | |
Frequency control range | 0.00~600.00Hz/0.0~3000.0HZ | |
Input frequency resolution | Digital input: 0.01Hz/0.1Hz Analog input: 0.1% of maximum frequency |
|
Speed control range | 1:50(VVF),1:200(SVC) | |
Speed control accuracy | Rated synchronous speed ± 0.2% | |
Acceleration and deceleration time | 0.01 s to 600.00 s / 0.1 s to 6,000.0 s / 1 s to 60,000 s | |
Voltage/frequency characteristics | Rated output voltage: 20% to 100%, adjustable Fundamental frequency 1Hz to 600Hz/3000Hz, adjustable |
|
Torque boost | Fixed torque boost curve Any V/F curve is acceptable. |
|
Starting torque | 150%/1Hz(VVF) 150%/0.25Hz(SVC) |
|
Precision torque control | ±5% rated torque (SVC) | |
Self-adjustment of output voltage | When the input voltage changes, the output voltage will basically remain unchanged. | |
Automatic current limit | Output current is automatically limited to avoid frequent overcurrent trips. | |
DC braking | Braking frequency: 0.01 to maximum frequency Braking time: 0~30S Braking current: 0% to 100% of rated current |
|
Signal input source | Communication, multi-speed, analog, etc. | |
Input and output | Reference power supply | 10V/20mA |
Terminal control power | 24V/100mA | |
Digital input terminal | 5-channel digital multi-function input: X1 to X5 X5 can be used as the high-speed pulse input (max. 100kHZ). |
|
Analog input terminal | 2-channel analog inputs: One (AI1) voltage source: -10 to 10V input; One channel (AI2): 0 to 10V input voltage or 0 to 20mA input current optional; |
|
Digital output terminal | Multi-function output of one open collector and one relay Maximum output current of the collector: 50mA; Relay contact capacity: 250VAC/3A or 30VDC/1A, EA-EC: normally open; EB-EC: normally closed |
|
Analog output terminal | One multi-function analog terminal output M1: 0-10V/0-20mA multi-function analog output terminal |
|
Operation panel | LED display | The LED digital tube displays relevant information about the inverter. |
Protection | Protective Function | Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, load loss, external fault, etc. |
Use conditions | Location | Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight. When the altitude is higher than 1km, it is derated by 1% per 100m. The maximum allowable altitude is 3km. |
Applicable environment | -10ºC to +60ºC, 5% to 95% RH (non-condensing). When the ambient temperature exceeds 50°C, it needs to be derated by 3% per 1°C temperature rise. The maximum allowable ambient temperature is 60°C. |
|
Vibration | Less than 0.5g | |
Storage environment | -40ºC~+70ºC | |
Installation method | Wall-mounted or installed in the cabinet | |
Protection level | Protection level | Standard IP20/IP21 (with plastic baffle) |
Cooling method | Cooling method | Forced air cooling |