The EM600 series inverter is a high-performance vector control inverter launched by SINEE. It supports three-phase AC asynchronous motors and permanent magnet synchronous motors; drive control technologies, such as the improved vector VF control technology (VVF), speed sensorless vector control technology (SVC) and speed sensor vector control technology (FVC); speed output and torque output; expansions such as I/O expansion cards, communication bus expansion cards and PG cards.
Item | Specification | |
Power supply | Rated voltage of power supply (400V) | 380V-20%~415V+20% |
Rated output current (690V) | 660V-15%~690V+10% | |
Rated voltage and frequency | 50-60Hz ± 5%; voltage unbalance rate: <3% | |
Output | Maximum output voltage | The maximum output voltage is the same as the input power voltage |
Rated output current | Continuous output of 100% rated current | |
Maximum overload current | 150% rated current: 60s; 180% rated current: 10s; 200% rated current: 2s | |
Basic control | Driving mode | V/F control (VVF); Speed sensorless vector control (SVC); Speed sensor vector control (FVC) |
Input mode | Frequency (speed) input, torque input | |
Start and stop control mode | Keyboard, control terminal (two-line control and three-line control), communication |
|
Frequency control range | 0.00~600.00Hz | |
Input frequency resolution | Digital input: 0.01Hz Analog input: 0.1% of maximum frequency | |
Speed control range | 1:50(VVF),1:200(SVC),1:1000(FVC) | |
Speed control accuracy | Rated synchronous speed ± 0.2% | |
Acceleration and deceleration time | 0.01 s to 600.00 s / 0.1 s to 6,000.0 s / 1 s to 60,000 s | |
Voltage/frequency characteristics | Rated output voltage: 20% to 100%, adjustable; fundamental frequency: 1Hz to 600Hz, adjustable |
|
Torque boost | Fixed torque boost curve, any V/F curve optional | |
Starting torque | 150%/1Hz(VVF),150%/0.25Hz(SVC),150%/0Hz(FVC) | |
Torque control accuracy | ±8% rated torque (SVC), ±5% rated torque (FVC) | |
Self-adjustment of output voltage | When the input voltage changes, the output voltage will basically remain unchanged |
|
Automatic current limit | Output current is automatically limited to avoid frequent overcurrent trips | |
DC braking | Braking frequency: 0.01 to maximum frequency Braking time: 0~30S Braking current: 0% to 100% of rated current |
|
Signal input source | Communication, multi-speed, analog, high-speed pulse, etc | |
Input and output | Reference power supply | 10V/20mA |
Terminal control power | 24V/200mA | |
Digital input terminal | 7 (standard X1 to X7) + 4 (extension card X8 to X11) digital multi-function inputs: X7 can be used as a high-speed pulse input terminal (F02.06 = 35/38/40); The remaining 10 channels (X1 to X6 and X8 to X11) can only be used as ordinary digital input terminals. |
|
Analog input terminal | 3 (standard AI1 to AI3) + 1 (extension card AI4) analog inputs: One (AI1) voltage source: 0 to 10V input; Two (AI2/AI3): 0 to 10V input voltage or 0 to 20mA input current optional; One (AI4) voltage source: -10V to 10V input |
|
Digital output terminal | 2 (standard Y1/Y2) + 1 (extension card Y3) open-collector multi-function outputs and 2 (R1: EA/EB/EC and R2:RA/RB/RC) relay multi-function outputs. Maximum output current of the collector: 50mA; relay contact capacity: 250VAC/3A or 30VDC/1A, with EA-EC and RA-RC normally open and EB-EC and RB-RC normally closed |
|
Analog output terminal | Two (M1/M2) multi-function analog output terminals, with output of 0 to 10V or 0 to 20mA | |
Operation panel | LED display | The LED digital tube displays relevant information about the inverter |
Parameter copying | Parameter settings of the inverter can be uploaded and downloaded for fast parameter copying | |
Protection | Protective Function | Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, overspeed, load loss, external fault, etc. |
Use conditions | Location | Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight |
Applicable environment | -10ºC to +40ºC, 20% to 90%RH (non-condensing) | |
Vibration | Less than 0.5g | |
Storage environment | -25ºC~+65ºC | |
Installation method | Wall-mounted, floor-standing electrical control cabinet, through-wall | |
Protection level | Protection level | Standard IP20/IP21 (450kW and above) |
Cooling method | Cooling method | Forced air cooling |